Alkalinity Analyzers ​ ​ ​

​ModelTechnology​Range(s)
 ​

6800T​

​Titration​​0-50, 50-200, 200-1,000, 0- >1,000 ppm or mg/l
 

Ammonia / Ammonium Analyzers ​ ​ 

​Model​​Range(s) ​ ​
LXT-​330-NH4​

​0.05 – 18,000 ppm

 

Chlorine Analyzers ​ ​ ​

​Model​Range(s)

CDA330

Chlorine:              0.05 – 20 ppm (High Range)
                              0.01 to 5 ppm (Low Range)
pH:                        0 to 14 pH​
FCA330​Free ​Chlorine:     0.05 – 20 ppm
pH:                        0 to 14 pH

TCA​330​

​Total Chlorine:     0.05 – 20 ppm
pH:                         0 to 14 pH​
 

Colorimeters ​ ​ ​

​ModelMethod​Range(s)
​ ​CA​600​​​​​Photometric Differential Absorbance​​Application Dependent
 

Conductivity ​ ​ ​

​Model​Range(s)
​ ​LXT-3300.055 µS – 2 S (Units: µS. mS, S; Auto Ranging​)
LXT-380​Chlorine Dioxide:      0.01 – 20 ppm
Conductivity:              0.055 µS – 2 S (Units: µS. mS, S; Auto Ranging​)​
Dissolved Oxygen:    000.1 – 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging​
ORP:                            -1,500 – +150 mV
pH:                               ​-1 – 15 pH​

pION:                          000.1 – 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 – 20 mega-ohms
Turbidity:                    0 – 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

Hydrocarbon In Water Analyzers ​ ​ ​

​Model​Range(s)
 
4080​​​0-10, 0-100, 0-1,000 pppm
Other ranges available
6650SP​​Application Dependent
6700E​0-5 to 20,000 mg/L
Single or Dual Range with external diluter
6700U​

​Per configuration

Liquid Chromatography ​ ​

​ModelSampling ConfigurationsDetectors​

Falcon GC​

Aspiration to inlet via sample pump​
​Process online via sample valve for gas or liquid*
Autosampler injections for liquid or heated headspace
Manual sy​ringe injection for gas or liquid
 
 
 
*Sample handling available
Dielectric Barrier Discharge (DBD)
​Flame Ionization (FID)
 
Flame Photometric (FPD)
 
Thermal Conductivity (TCD)
 

Nitrates Analyzers ​ ​

​Model​Range(s)
LXT-330-N​​0.1 – 1,000 ppm

Oil in Water Analyzer

​​

​Model​Range(s)
4080​​​​0-10, 0-100, 0-1,000 pppm
Other ranges available

6650SP​

 

​Application Dependent
6700E​0-5 to 20,000 mg/L
Single or Dual Range with external diluter
6700U​​Per configuration

Organics Analyzer

​Model​Range(s)
​ 
6700U​Per Configuration

Oxidation / Reduction Potential

​Model​Range(s)
​ ​LXT-330​-1500 – +1500 mV

LXT-380​

Chlorine Dioxide:      0.01 – 20 ppm
Conductivity:              0.055 µS – 2 S (Units: µS. mS, S; Auto Ranging​)​
Dissolved Oxygen:    000.1 – 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging​
ORP:                            -1,500 – +150 mV​
pH:                               ​-1 – 15 pH​
pION:                          000.1 – 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 – 20 mega-ohms
Turbidity:                    0 – 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

Oxygen (Dissolved) Analyzers

​Model​Range(s)
​ ​LXT-330000.1 – 999.9 ppb, ppm, %SAT, mg/L; Auto Ranging

​LXT-380​

Chlorine Dioxide:      0.01 – 20 ppm
Conductivity:              0.055 µS – 2 S (Units: µS. mS, S; Auto Ranging​)​
Dissolved Oxygen:    000.1 – 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging​
ORP:                            -1,500 – +150 mV​
pH:                               ​-1 – 15 pH​
pION:                          000.1 – 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 – 20 mega-ohms
Turbidity:                    0 – 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

pH

​Model​Range(s)
​ ​LXT-330

​-1 – 15 pH​


LXT-380​

Chlorine Dioxide:      0.01 – 20 ppm
Conductivity:              0.055 µS – 2 S (Units: µS. mS, S; Auto Ranging​)​
Dissolved Oxygen:    000.1 – 999.9 ppb, ppm, %S​AT, mg/L; Auto Ranging​
ORP:                            -1,500 – +150 mV​
pH:                               ​-1 – 15 pH​
pION:                          000.1 – 999.9 ppb, ppm, ppt, Auto Ranging
Resistivity:                  0.001 – 20 mega-ohms
Turbidity:                    0 – 4,000 NTU NTU, FNU, mg/L, ppm, % Solids,
                                     Auto Ranging
Temperature:            3 K-ohm TC, -22° to 284°F (-30° to 140°C)

Suspended Solids / Turbidity Analyzers

​Model​Range(s)
​ ​

LXT-330​

0 – 4,000 NTU, FNU, mg/L, ppm, % Solids, Auto Ranging

Total Organic Carbon

​Model​Range(s)
  
6700E​​0-5 to 20,000 mg/L
Single or Dual Range with external diluter
​​6700U​Per Configuration

Water Cut / BS&W

​​Model​Range(s)
​ ​5650​​0-25% to 0-100%